Virage® OCT Spinal Fixation System

insetimage_Spine_Virage_01
The Virage System is an Occipital-Cervico-Thoracic (OCT) spinal fixation system featuring the innovative 360° Extreme-Angle Omnidirectional Screw that simplifies rod alignment and minimizes operating time.

Flexibility

  • The Virage OCT System offers the widest range of screw diameters for use in longer constructs
  • The Extreme Angle Omnidirectional screw allows for 56° of angulation and 112° of conical range of motion designed to facilitate optimal screw placement
  • Multiple rod options include Cobalt Chrome and Titanium materials, pre-cut and pre-bent rods and pre-bent and articulating occipital rods
  • Head-to-head connectors provide multi-planar motion, allowing for off-axis screw head positioning

 

Efficiency

  • Double-lead screw accelerates insertion
  • Omnidirectional screw simplifies rod placement and minimizes operating time
  • Friction-fit head holds the desired rod position and facilitates rod placement

 

Safety

  • Varying thread forms maximize screw interaction with various bone densities
  • The Virage OCT System has demonstrated to have increased pull-out strength when compared to competitive systems. (Test data on file at Zimmer Biomet Spine, Inc.)

DESCRIPTION

The Zimmer Biomet Spine Virage™ OCT Spinal Fixation System is a posterior system intended for the Occipital-Cervical-Thoracic spine (Occiput-T3). The system consists of a variety of rods, anchors, transverse connectors, screws, and polyaxial screws to achieve an implant construct as necessary for the individual case. The system also includes the instruments necessary for inserting and securing the implants. The implant system is intended to be removed after solid fusion has occurred.

The Virage System implants are fabricated from medical grade titanium alloy and medical grade cobalt chromium alloy. Implants made from medical grade titanium, medical grade titanium alloy, and medical grade cobalt chromium may be used together. Never use titanium, titanium alloy, and/or cobalt chromium with stainless steel in the same construct. All implants are single use only and should not be reused under any circumstances.

Refer to the Virage OCT Spinal Fixation System Surgical Technique manual for additional information on how to use this device. Contact your Zimmer Biomet Spine Sales Representative or Zimmer Biomet Customer Service for a copy of the current Surgical Technique.

INDICATIONS

The Virage OCT Spinal Fixation System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1-C7) and the thoracic spine from T1-T3; traumatic spinal fractures and/or traumatic dislocations; instability of deformity; failed previous fusions (e.g., pseudoarthorsis); tumors involving the cervical spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability. The Virage OCT Spinal Fixation System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advance stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

In order to achieve additional levels of fixation, The Virage OCT Spinal Fixation System may be connected to the Instinct Java and Sequoia Spinal Systems offered by Zimmer Biomet Spine, using rod connectors and transition rods. Refer to the Instinct Java and Sequoia Spinal System package insert for a list of the system specific indications of use.

The titanium Lentur™ Cable System to be used with the Virage OCT Spinal Fixation System allows for cable attachment to the posterior cervical or thoracic spine.

CONTRAINDICATIONS

The Virage System is not designed or sold for any use except as indicated. DO NOT USE THE VIRAGE SYSTEM IMPLANTS IN THE PRESENCE OF ANY CONTRAINDICATION.

Contraindications include, but are not limited to:

  1. Overt infection or distant foci of infections.
  2. Local inflammation, with or without fever or leukocytosis.
  3. Pregnancy.
  4. Morbid obesity.
  5. Rapid joint disease, bone absorption, osteopenia, and/or osteoporosis.
  6. Suspected or documented metal allergy or intolerance.
  7. Any time implant utilization would interfere with anatomical structures or expedited physiological performance, such as impinging on vital structures.
  8. Severe comminuted fractures such that segments may not be maintained in satisfactory proximate reduction.
  9. Use in displaced, non-reduced fractures with bone loss.
  10. The presence of marked bone absorption or severe metabolic bone disease that could compromise the fixation achieved.
  11. Poor prognosis for good wound healing (e.g., decubitis ulcer, end-stage diabetes, severe protein deficiency, and/or malnutrition).
  12. Any case not needing a bone graft or fusion.
  13. Any case not described in the indications.

 

WARNINGS AND PRECAUTIONS

Following are specific warnings, precautions, and adverse effects associated with use of the Virage System that should be understood by the surgeon and explained to the patients. General surgical risk should be explained to the patients prior to surgery.

  • Implantation of the Virage System should be performed only by experienced spinal surgeons
  • All implants are intended for single use only. Single use devices should not be re-used. Possible risks associated with re-use of single-use devices include:
    • Mechanical malfunction
    • Transmission of infectious agents
  • Metal sensitivity has been reported following exposure to orthopedic implants. The most common metallic sensitivities (nickel, cobalt, and chromium) are present in medical grade stainless steel and cobalt-chrome alloys.
  • The Virage System is a temporary internal fixation device. Internal fixation devices are designed to stabilize the operative site during the normal healing process. After healing occurs, these devices serve no functional purpose and should be removed. Implant removal should be followed by adequate postoperative management to avoid fracture or refracture.
  • Universal precautions should be observed by all end users that work with contaminated or potentially contaminated medical devices. Caution should be exercised when handling devices with sharp points or cutting edges to prevent injuries during and after surgical procedures and reprocessing.
  • Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.
  • Precaution: The implantation of spinal fixation systems should be performed only by experienced spinal surgeons with specific training in the use of these spinal systems because this is a technically demanding procedure presenting a risk of serious injury to the patient. Preoperative planning and patient anatomy should be considered when selecting implant diameter and length.

Additional preoperative, intraoperative, and postoperative warnings and precautions:

PREOPERATIVE

  • PRE-OP PLANNING – Use of cross sectional imaging (i.e., CT and/or MRI) for posterior cervical screw placement is recommended due to the unique risks in the cervical spine. The use of planar radiographs alone may not provide the necessary imaging to mitigate the risk of improper screw placement. In addition, use of intraoperative imaging should be considered to guide and/or verify device placement, as necessary.
  • Usage of automated cleaning processes without supplemental manual cleaning may not result in adequate cleaning of instruments.
  • Proper handling, decontamination (including pre-rinsing, washing, rinsing and sterilization), storage and utilization are important for the long and useful life of all surgical instruments. Even with correct use, care and maintenance, they should not be expected to last indefinitely. This is especially true for cutting instruments (e.g., bone awls/drills) and driving instruments (e.g., drivers). These items are often subjected to high loads and/or impact forces. Under such conditions, breakage can occur, particularly when the item is corroded, damaged, nicked or scratched.
  • Prior to use, instruments should be visually inspected for wear and tested to assure they are functioning properly. If instruments are discolored, show evidence of corrosion, have loose screws/pins, are out of alignment, are cracked or have other irregularities, Do Not Use. Instrumentation that appears damaged should be returned to the manufacturer.
  • Never use titanium, titanium alloy, and/or cobalt chromium with stainless steel in the same implant construct; otherwise, galvanic corrosion may occur. See DESCRIPTION section for Virage System materials and compatibility information.

 

INTRAOPERATIVE

  • If contouring of the implant is necessary for optimal fit, the contouring should be gradual and avoid any notching or scratching of the implant surface. Do not repeatedly or excessively bend the implant. Do not reverse bend the plate or rods.
  • Bending Plate outside of bend zone groove may result in cracking of Plate. Surgeon should always inspect Plate before implanting.
  • Occiput and pedicle bone integrity should be verified
  • Care should be taken during occiput and pedicle preparation to avoid penetrating too deep.
  • Care should be taken to ensure occipital screw is not driven in too deep
  • Care should be taken during bone preparation to avoid damage to the pedicle and to the surgical instruments.
  • Care should be taken to minimize soft tissue damage during surgery.
  • Care should be taken to avoid removing excess material from the Lamina.
  • Care should be taken to avoid cross-threading screws and closure tops.
  • If any implant or instrument comes in contact with a non-sterile surface it should not be used.

 

POSTOPERATIVE

  • Adequately instruct the patient. Postoperative care and the patient’s ability and willingness to follow instructions are one of the most important aspects of successful bone healing. The patient must be made aware of the limitations of the implant and that physical activity and full weight bearing have been implicated in fracture. The patient should understand that an implant is not as strong as normal, healthy bone and will fracture if excessive demands are placed on it in the absence of complete bone healing. An active, debilitated, or demented patient who cannot properly use weight-supporting devices may be particularly at risk during postoperative rehabilitation.
  • The Virage System is a temporary internal fixation device. Internal fixation devices are designed to stabilize the operative site during the normal healing process. After healing occurs, these devices serve no functional purpose and should be removed. Implant removal should be followed by adequate postoperative management to avoid fracture or refracture.

 

ADVERSE EFFECTS

  • Complications and adverse reactions have been reported with the use of similar spinal instrumentation systems. These adverse effects, including the possibility of death, should be discussed with the patient prior to surgery.
  • Possible neurologic operative/postoperative adverse reactions that may require medical or surgical intervention (e.g., implant removal with or without re-instrumentation) include:
  • Paralysis, complete or incomplete. Delayed onset has occurred even when evoked potential was unaffected during surgery
  • Dural tear leading to cerebrospinal fluid fistula or pseudo meningocele
  • Other spinal cord injuries not otherwise described due to positioning of the spinal attachment device
  • Laminar erosion
  • Epidural bleeding
  • Abnormal sensations
  • Radiculopathy

 

Possible device postoperative complications/adverse reactions that may require medical or surgical intervention (e.g., implant removal with or without re-instrumentation) include:

  • Loosening, bending, breaking, disassembly, and/or migration of the components
  • Collapse of a fracture and/or fusion site
  • Device failure
  • Corrosion at the screw/locking cap interface contributing to breakage, and/or pseudoarthrosis
  • Discomfort or pain, soft tissue erosion, or protrusion due to prominent implanted hardware
  • Attachment device pullout, especially with short constructs and osteoporotic bone
  • Implant or graft extrusion through the skin
  • Postural deformities, pain, skin breakdown, or residual neural compression due to kyphosis or lordosis occurring at the top of the segment being instrumented
  • Bone loss or fracture due to stress shielding
  • Foreign body reaction to the device including tumor formation, autoimmune disease, metallosis, and/or scarring
  • Non-union or pseudoarthrosis
  • Cessation of growth at the fusion site
  • Discitis, arachnoiditis, and/or other types of inflammation

 

Possible general or local postoperative complications/adverse reactions that may require medical or surgical intervention (e.g., implant removal with or without re-instrumentation) include:

  • Hemothorax
  • Deep vein thrombosis, thrombophlebitis, and/or pulmonary embolism that may be fatal; may be due to patient position and/or length of the surgical procedure
  • Decubitus ulcer
  • Wound infection, deep or superficial, which may require implant removal and/or other medical interventions
  • Wound dehiscence, delayed wound healing, or hematoma
  • Pain, possibly severe in nature
  • Urinary tract infection
  • Blood vessel damage and/or blood loss or hemorrhage
  • Fracture(s) of the bone
  • Gastrointestinal, urological, and/or reproductive system compromise including sterility, impotency, and/or loss of consortium
  • Bone graft donor site pain
  • Inability to resume activities of normal daily living

Legal Manufacturer:

Zimmer Biomet Spine, Inc.
10225 Westmoor Dr.
Westminster, CO 80021 USA


All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.  
This material is intended for health care professionals.  Distribution to any other recipient is prohibited.
For product information, including indications, contraindications, warnings, precautions, potential adverse effects and patient counseling information, see the package insert and information on this website. To obtain a copy of the current Instructions for Use (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support.